Sizes the depth shown of the box gutter is the depth at the upstream end.
Box gutter sump regulations.
Have a minimum depth of 75mm at the high end.
Read more about compliant guttering options what does it mean for installers.
Have a sole width which is not reduced discharge at the downstream end without.
The minimum size of a sump is 400mm x 200mm minimum width of box gutter and 150mm deep.
Box gutters must be straight no bends.
Vertical faces enter the full vertical face area.
Must have a constant slope between 1 40 and 1 200.
Experiment with this figure to get the depth of box gutter you require.
Trial box gutter width the minimum width allowed for domestic projects is 200mm.
This will prevent water damage in the event of gutters overflowing either due to high rainfall or a blockage.
Sides must be vertical.
Down pipe must be vertical from sump not to the side minimum sump length is 400mm.
Have a minimum width of 300mm for commercial installations 200mm for domestic installations.
However any width can be entered.
For the associated box gutter outlet.
For commercial projects the minimum allowable width is 300mm.
State of victoria victorian building authority 2017 published june 2017.
Sumps are to be appropriately sized in accordance with as nzs 3500 3 with a minimum length of 400 mm and when fitted with a high capacity overflow device with a depth of not less than 150 mm when either one or two box gutters enter the sump.